Transdermal Hair Removal Information

Electrolysis

Equipment.com


Order Catalog _]


Consultation _]


Transdermal _]


Microlysis _]


Topical Kits _]


RF Tweezers _]


Micro Probe _]


Laser Epilation _]


Depilatories _]


Supply Items _]



Sales Department _]



Technical Support _]



Administration _]



Shipping Inquiry _]



Payment Options _]



Privacy Policy _]



Comment Page _]



Press Releases _]



Affiliate Program _]



Satisfaction Guarantee _]



We accept 130 different currencies!




©1996-2007 Electrolysis Equipment.com



Fax: 419.710.4577



Hassle-Free shipping!  No Duties or Taxes payable upon delivery!

 

You will see the entire click-to-door cost of your order on our Checkout page.


 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transdermal Electrolysis System Requirements

 

Electrolysis Equipment and Accessory Specifications


Aavexx 300 Precision Electrolysis System

Precision Medical Electrolysis/Electrophoresis Power System capable of 2,500 to 5,000μa of total output power at 60-70 cycles (Hz), automatic overload protection, in-line 5000μa in line fast acting fuse, 105 to 118 Volts.  Electrical Pressure, Output Range: 300K to 18,000KµV (10V-6).  Adjustable Intensity, Output Range: 0.01-5,000mA (0-100ω)(10A-3).

Recommended Manufacturer:  Aavexx Precision Power Systems, UK

Additional Recommendations:  Multiple output system is preferred for greater versatility.

When choosing your Transdermal electrolysis setup, it will be necessary to avoid using low pressure driver devices (below 10,000KµV).  The human body has a constant “ohms” factor present, meaning it is highly resistant to the conductivity of electrical current.  Low impulse systems (Transdermal “home devices”)  simply do not produce enough electrical pressure to drive adequate Watts for effective treatment.  Home use systems by IGIÁ Forever Gone Plus, IGIÁ Touch 'N' Go and E-Pen from AsonTV use very low power systems (1,000 to 9000KµV) and should be avoided.

Another major area for consideration involves the cycles per second, also called Hertz, of the driver module.  The frequency modulation of the galvanic current determines actual intensity (independent of voltage, which is measured in Watts).  Should your precision medical electrolysis system operate under 40 cycles per second, the actual level of electrolysis occurring in treatment will be substantially reduced (even if your meter is showing adequate amperage for treatment).  You will need 60 Hz or higher to kill follicles with Transdermal electrolysis.  Low priced manufacturers Permanex and Vector use low (or no) frequency modulation and should be avoided.

The few precision medical power systems available, which are suitable for Transdermal electrolysis procedures, should be also capable of performing Electrophoresis and DNA sequencing.  These are generally high-end systems, but rest assured that they are designed for specialized applications.  Always remember, professional equipment gives professional results.


Transdermal Electrolysis Accessory Requirements:  Positive Dermal Contact Electrode and Attachment Assembly. 
 

Treatment Instruments:  Swab Applicator, micro-clips, insulated galvanic tweezers, standard tab-type resting electrodes and attachment assembly, and low/high viscosity silver chloride electrolyte gel. 


[ Clinical Results ]  [ Transdermal Textbook ]  [ Aavexx Electrolysis Equipment ]  [ Transdermal Accessories and Supplies ]   [ System Requirements ]  [ Science and History ]


Permanent Removal of Unwanted Hair - Without the Pain

Instead of inserting a needle, Transdermal hair removal involves placing a patch to transmit galvanic current through the skin to the hair follicles. This current creates a chemical reaction changing the water & salt present in the hair follicle to sodium hydroxide. As in the case of electrolysis, the sodium hydroxide destroys the germinative cells, thus achieving permanent hair removal.

    What Are The Advantages Over Electrolysis?

  • Permanent hair removal without the pain of a needle.

  • No swelling, bruising, scabbing or scarring.

  • Excellent on distorted & ingrown hairs.

  • Makeup can be worn soon after treatment.

  • You can treat the entire area each time you use the system.

  • NO risk of infection.

  • It treats the hair below the surface as well as above.

Points to Remember!
 
As it takes approximately 6 - 12 weeks for a hair to grow from the papilla to the surface of the skin, and each hair has its own individual cycle, you can appreciate why electrolysis is required over a period of time.  You may also be unaware that there can be as many as 1000 hair follicles in a square inch but only 10% are above the surface at any one time. 

Excessive hair growth can be attributed to many causes such as hereditary, stress, hormonal changes or even medications.  In the case of women, puberty, pregnancy and menopause can affect hair growth, for these reasons, no-one - not even your doctor - can predict the exact length of time it will take to achieve complete removal of hairs in an area.    

 

 - Fax 1.419.710.4577 -    [Order Online or by Fax,  24 Hours a Day]     - Fax 1.419.710.4577 -

Currency Exchange Rates:  Euro, Yen, Pounds, DMarcs, Francs, Lire, Riyas, Pesos, and More